Product Specifications
System Items Spec

Analyical System

Throughput
900 Tests/Hr
Simultaneous Test Items 60 Items/Sample ;64 Items/Sample (w/ISE)
Analytical Methods

End-point 1 / End-point 2 / Rate 1 / Rate 2

Sampling System

Sampling

Micro-syringes 
Metal probe with sensing capability
Sample Volume 2-50μL / Chemistry test (Smallest precision unit = 0.1μL)
Max. 50μL as total volume (sample + diluent)
Sample Identification
Barcode : Code 39, Code 128, 2/5 interleaved
Refrigerated STAT Disc
1.30-Sample capacity
2.Also available for serum and control
Sample Preparation Rack system (5 Samples / rack)
Max. of 60 samples ;Can be loaded anytime
Specimen (serum or urine) distinguished by ID number
Dead Volume
80 μL or more (Conical cup)
250 μL or more (Primary tubes : 13*75mm)
Data Entry Test requisition : Max. 20,000 samples
Data storage : Max. 1,000,000 test results

Cal/QC System

Calibration

Standard solution or control serum : Max. 200 kinds (Max. 6 points per chemistry)

Quality Control

Control serum : Max. 30 kinds

Reagent System

Reagent Storage

R1 Disc & R2 Disc
‧ Reagent ID (barcode)
‧ Sequential usage available
‧ Temperature : 5℃-12℃

Reagent Dispensing 1. Micro-syringes
2. Probes with sensing capability
Reagent Volume 25μL~300μL per dispense (R1 + R2 ≦ 400μL)
Reagent Bottle Max. 60 bottles each disc. Bottles size :25 C.C. / 50 C.C. / 100 C.C.
Reagent Remaining Automated check of volume for possible test counts
Mixing
Mixing stirrer (wash and air-blow)

Reaction System

Photometry Method

Grating system
Photometric Wavelength

Separate photodetectors are available for the following wavelengths: 340 , 380 , 410 , 450 , 480 , 505 , 546 , 570 , 600 , 630 , 660 , 700 , 750 , 800 , 850nm (15 discrete wavelengths).

Lamp
1. Halogen lamp (12V/30W)
2. Shelf-life : 1,000 hours in average
Cuvette

PMMA.+VHS(light-path : 5mm ; volume : 600μL)
200 cuvettes in total

Reaction Temperature

1. Incubation Bath : 37℃±0.1℃
2. Displayed on the instrument and the touchscreen

Minimum Volume For Measurement 40μL (w/o ISE) ;100μL (w/ISE)
Measuring Time 8 sec per point ; total Photometric point : 90
Absorbance Range 0-2.5
Reaction Volume 200μL ~ 450μL (R1 + R2 ≦ 400μL)
Reaction Time 12 mins
Chemistries Performable 1.Colorimetry routine chemistries
2.Turbidimetry : IgG/IgM/IgA ...
3.Latex : RF/CRP/ASO ...
4.Homogeneous EIA (EMIT) : DAU/TDM ...
5.ISE : Na / K / CI / Li / Co2
Site requirements

Dimensions

Analyzer : 1800mm (W) *1300mm (H) *1050mm (D)

Weight Approx. 500Kg
Power Requirements Voltage : AC 110 or AC 220V (±10%)
Frequency : 50-60 Hz
Power Consumption 4.0 KVA
Grounding Grounded with a type 3 connector

Standard Ambient Temperature

15℃~32℃

Standard Ambient Humidity

40~80% RH (non-condensing atmosphere)
DI Water Quality 10 mΩ‧cm
DI Water Supply Water pressure 0.5kgf/cm²-3.5 kgf/cm²
Draining System Automated pressure drain
Water Consumed 40 L/hr
Warm-up & Stand-by 24-Hour availability
Warm-up time : 20 mins
On-line Current loop or RS232C